opentrons-magnetic-block

Opentrons Magnetic Block for Flex - unpowered magnetic bead separation using gripper-based labware movement with high-strength neodymium magnets for DNA/RNA purification, immunoprecipitation, and bead-based workflows

jkitchin · 已有静态检查记录

安装与使用

运行命令前先阅读来源与依赖说明。复制命令不会自动安装或执行。

npx skills add jkitchin/knowhow --skill opentrons-magnetic-block

技能说明


name: opentrons-magnetic-block description: Opentrons Magnetic Block for Flex - unpowered magnetic bead separation using gripper-based labware movement with high-strength neodymium magnets for DNA/RNA purification, immunoprecipitation, and bead-based workflows allowed-tools: ["*"]

Opentrons Magnetic Block

Overview

The Opentrons Magnetic Block is an unpowered, 96-well magnetic separator exclusively for Opentrons Flex. It uses high-strength neodymium magnets to pull magnetic beads to the side of wells, enabling supernatant removal for DNA/RNA purification, protein cleanup, immunoprecipitation, and other bead-based separation protocols.

Core value: Automate magnetic bead-based purification workflows without manual plate transfers. Combine gripper-based plate movement with magnetic separation for fully automated DNA extraction, PCR cleanup, and bead-based assays.

Platform: Opentrons Flex only (not compatible with OT-2)

When to Use

Use the Magnetic Block skill when:

  • Performing DNA/RNA extraction with magnetic beads
  • PCR product cleanup (AMPure, SPRIselect beads)
  • Magnetic bead-based library preparation (NGS)
  • Protein purification or immunoprecipitation with magnetic beads
  • Cell sorting or enrichment with magnetic particles
  • Any protocol requiring magnetic bead separation

Don't use when:

  • Working with OT-2 robot (Magnetic Block is Flex-only)
  • Need vertical bead movement within solution (block only pulls to side)
  • Require heated magnetic separation
  • Working without Opentrons Flex gripper

Quick Reference

OperationMethodKey Parameters
Load moduleprotocol.load_module()"magneticBlockV1", location
Move plate to blockprotocol.move_labware()labware, mag_block, use_gripper=True
Wait for separationprotocol.delay()minutes (typically 2-5)
Pipette supernatantpipette.transfer()source, dest
Move plate off blockprotocol.move_labware()labware, new_location, use_gripper=True

Platform Requirements

Opentrons Flex only

  • API version: 2.15 or later (Magnetic Block introduced)
  • Gripper required: All plate movement uses gripper
  • Robot type: Must specify "robotType": "Flex"

Key Characteristics

Unpowered Design

Important: The Magnetic Block is completely unpowered:

  • No electronic control
  • No on/off switching
  • Always magnetic when plate is present
  • Robot and Opentrons App are not aware of magnetic state

Implication: All control is manual through:

  • Physical plate positioning (gripper movement)
  • Timed delays for bead separation
  • Pipetting operations

Loading the Module

from opentrons import protocol_api

metadata = {'apiLevel': '2.19'}
requirements = {"robotType": "Flex", "apiLevel": "2.19"}

def run(protocol: protocol_api.ProtocolContext):
    # Load Magnetic Block
    mag_block = protocol.load_module(
        module_name="magneticBlockV1",
        location="D1"
    )

    # Load compatible labware
    mag_plate = mag_block.load_labware(
        name="biorad_96_wellplate_200ul_pcr"
    )

Compatible deck slots: Any Flex slot (A1-D3) Recommended: D1, D2, or D3 (bottom row for workflow efficiency)

Compatible Labware

The Magnetic Block works with 96-well plates that fit the magnetic footprint:

Common compatible labware:

  • biorad_96_wellplate_200ul_pcr
  • nest_96_wellplate_100ul_pcr_full_skirt
  • opentrons_96_wellplate_200ul_pcr_full_skirt
  • Other 96-well PCR plates with standard footprint

Important:

  • Labware must be grippable (compatible with Flex gripper)
  • Wells must align with magnet positions
  • Standard 96-well footprint required

Basic Magnetic Separation Workflow

Step 1: Load Sample Plate

# Start with sample plate on deck (not on magnetic block yet)
sample_plate = protocol.load_labware("biorad_96_wellplate_200ul_pcr", "C1")

# Add magnetic beads and binding buffer
pipette.transfer(10, bead_stock, sample_plate.wells())
pipette.transfer(100, binding_buffer, sample_plate.wells(), mix_after=(5, 80))

Step 2: Incubate for Binding

# Incubate to allow beads to bind target (DNA/RNA/protein)
protocol.delay(minutes=5)

# Optional: Mix during incubation (use Heater-Shaker)

Step 3: Move to Magnetic Block

# Move plate to magnetic block using gripper
protocol.move_labware(
    labware=sample_plate,
    new_location=mag_block,
    use_gripper=True
)

Step 4: Wait for Bead Separation

# Allow beads to collect at side of wells
protocol.delay(minutes=3)

# Beads are now held at well edges by magnets

Step 5: Remove Supernatant

# Pipette supernatant while beads are held by magnets
pipette.transfer(
    volume=110,
    source=sample_plate.wells(),
    dest=waste.wells(),
    new_tip="always"
)

# Beads remain in wells, held by magnetic field

Step 6: Move Off Magnetic Block

# Move plate off magnets for bead resuspension
protocol.move_labware(
    labware=sample_plate,
    new_location="C2",
    use_gripper=True
)

# Beads are now free to resuspend

Step 7: Wash and Repeat

# Add wash buffer
pipette.transfer(150, wash_buffer, sample_plate.wells())

# Mix to resuspend beads
pipette.mix(repetitions=5, volume=100, location=sample_plate.wells())

# Return to magnetic block
protocol.move_labware(sample_plate, mag_block, use_gripper=True)

# Wait for separation
protocol.delay(minutes=2)

# Remove supernatant
pipette.transfer(150, sample_plate.wells(), waste.wells(), new_tip="always")

Step 8: Elute

# Move off magnets
protocol.move_labware(sample_plate, "C2", use_gripper=True)

# Add elution buffer
pipette.transfer(50, elution_buffer, sample_plate.wells(), mix_after=(5, 30))

# Incubate
protocol.delay(minutes=2)

# Final magnetic separation
protocol.move_labware(sample_plate, mag_block, use_gripper=True)
protocol.delay(minutes=2)

# 