epd-to-spec
Write CSI specification language for EPD submittals and sourced GWP limits. Use to add embodied-carbon or EPD requirements to specs; not to parse, find, or compare EPDs.
AlpacaLabsLLC · 已有 AI 审核记录
安装与使用
运行命令前先阅读来源与依赖说明。复制命令不会自动安装或执行。
npx skills add AlpacaLabsLLC/skills-for-architects --skill epd-to-spec技能说明
name: epd-to-spec description: Write CSI specification language for EPD submittals and sourced GWP limits. Use to add embodied-carbon or EPD requirements to specs; not to parse, find, or compare EPDs. allowed-tools:
- Read
- Write
- Edit
- Bash
- Glob
- Grep
- AskUserQuestion
/as:epd-to-spec — EPD Specification Writer
Harness note: use
/as:<skill>on Claude Code and$<skill>on Codex. Resolve<skill-root>as the directory containing this loadedSKILL.mdand<plugin-root>as the plugin root that containsskills/, and use equivalent native tools when host tool names differ.
Takes EPD data, GWP limits, or a materials list and generates CSI-formatted specification sections that require Environmental Product Declarations and set maximum Global Warming Potential thresholds. Output follows the same three-part CSI SectionFormat used by /as:spec-writer.
EPD fields follow schema/epd-schema.md. Accept pasted structured values, direct handoffs from /as:epd-parser or /as:epd-compare, or a validated project-local epd-library.csv; do not require a library.
Project context
If PROJECT.md exists in the working directory, read it before fetching, then scan decisions/*.md directly for GWP thresholds or material choices the spec must reflect. After completing, offer chosen thresholds to /as:project update for its Code section, each with a source and date. If a threshold was chosen here, propose /as:project record-decision. No PROJECT.md? Skip silently — or mention /as:project init if the user is clearly starting a project.
Input
The user provides one or more of:
- Material list with GWP limits — "concrete max 350 kg CO2e/m3, rebar max 1.0 kg CO2e/kg"
- EPD data — pasted values, a direct handoff, or "use the EPDs in my project library to set thresholds"
- Comparison report — "use the lowest GWP from my last comparison as the max"
- LEED target — "we're pursuing LEED v4.1 MRc2 Option 2"
- Verbal description — "write EPD requirements for a ground-up office, concrete and steel structure, curtain wall"
- Project type — helps determine which CSI divisions need EPD language
If the user invokes the skill without input, ask:
- What materials need EPD requirements? (paste a list, reference a direct EPD result or local EPD CSV, or describe the project)
- Do you have specific GWP thresholds, or should I use published industry baselines (cited with named source and publication year)?
CSI Divisions Where EPDs Are Most Common
Map materials to the correct division. EPD requirements are most relevant for structural, envelope, and interior finish materials:
| Division | Title | Common EPD Products |
|---|---|---|
| 03 30 00 | Cast-in-Place Concrete | Ready-mix concrete |
| 03 40 00 | Precast Concrete | Precast panels, structural precast |
| 03 41 00 | Precast Structural Concrete | Precast beams, columns |
| 05 12 00 | Structural Steel Framing | Hot-rolled steel, HSS |
| 05 21 00 | Steel Joist Framing | Open web steel joists |
| 05 31 00 | Steel Decking | Composite floor deck, roof deck |
| 05 50 00 | Metal Fabrications | Miscellaneous metals, rebar |
| 06 10 00 | Rough Carpentry | Dimensional lumber, engineered wood |
| 06 17 00 | Shop-Fabricated Structural Wood | Glulam, CLT, LVL |
| 07 21 00 | Thermal Insulation | Mineral wool, XPS, EPS, spray foam |
| 07 27 00 | Air Barriers | Fluid-applied, sheet membranes |
| 07 42 00 | Wall Panels | Metal wall panels, ACM |
| 07 54 00 | Thermoplastic Membrane Roofing | TPO, PVC |
| 08 44 00 | Curtain Wall / Glazing | Aluminum curtain wall, IGUs |
| 09 21 00 | Plaster and Gypsum Board | Gypsum board, joint compound |
| 09 30 00 | Tiling | Porcelain, ceramic tile |
| 09 51 00 | Acoustical Ceilings | ACT, mineral fiber |
| 09 65 00 | Resilient Flooring | LVT, rubber, linoleum |
| 09 68 00 | Carpeting | Carpet tile, broadloom |
| 32 12 00 | Asphalt Paving | HMA, WMA |
Spec Generation Workflow
Step 1: Parse and classify materials
Read the user's input and build an inventory:
- Material/product — as provided
- CSI division and section number — mapped from the material type
- GWP threshold — user-provided limit, EPD value, or industry baseline
- Declared unit — must match the unit used in the GWP threshold
If the user provided EPD data or a comparison report, extract the GWP values and declared units from there. Validate any epd-library.csv with python3 "<plugin-root>/skills/master-schedule/scripts/csv-library.py" validate epd; reject the FF&E schema. Validation is read-only; never invoke init, import, append, or update.
If no GWP thresholds are specified, a published industry-average baseline may be used only when you can cite its named source and publication year (per the GWP Baseline Policy below) — always flag such thresholds [VERIFY THRESHOLD]. If no citable baseline is available, do not use approximate from-memory numbers. Instead, ask the user:
"I need GWP thresholds to write the spec. You can provide them by:
- Sharing an EPD — I'll extract the GWP value and declared unit
- Using
/as:epd-research— I'll find EPDs for your material categories - Using
/as:epd-compare— compare products and pick a threshold from the results - Stating a number — e.g., 'concrete max 350 kg CO2e/m3'
We're working on EC3 API integration that will automate baseline lookups — for now, provide an EPD or a specific threshold."
Do not fall back to uncited hardcoded numbers. Write the spec with [THRESHOLD TBD] placeholders if the user asks to proceed without data, and flag every placeholder clearly.
Report the mapping:
Identified X materials across Y divisions:
- 03 30 00 Cast-in-Place Concrete: GWP max 350 kg CO2e/m3 (user-provided)
- 05 12 00 Structural Steel Framing: GWP max 1.16 kg CO2e/k
阅读完整来源 ↗